Basic Info.

Model NO.
JDC-H

Housing Length
<=5.88m

Product Type
Single Pole Insulator

Product Name
Conductor Bar

Housing Material
PVC, Aluminum Alloy

Transport Package
Standard Packing

Specification
ISO9001

Trademark
Zhongyuan Shengqi

Origin
China

HS Code
73030090

Production Capacity
10000 Meters Per Month

Product Description

Jdc-H Type Conductor Bar for Single Pole Insulated Conductor Bar
Introduction&colon;

Jdc-H Type Conductor Bar for Single Pole Insulated Conductor Rail is a modern power supply system using single-pole insulated conductor rails&period; It complies with the latest regulations and provides the electric energy for mobile consumers&period; The conductor rail material is cooper &lpar;200A-3000A&rpar;&period; The aluminium conductor rail is provided with a proven and patented stainless steel contact surface&period; Any numbers of poles can be installed vertically or horizontally&comma; on straight or curved systems&period;

The conductor rail system can be installed indoor or outdoor&period; For high temperature conditions&comma; a high temperature insulation cover up to &plus;115ºC is available&comma; also for low temperature conditions&comma; it could be up to -40ºC&period;

The entire conductor rail system is insulated to current safety regulations&comma; it is entirely protected against direct contact&period; Ground insulation cover is marked yellow-green on one side over the entire length of the rail&period;
Type-R&colon; Curves for R&geq;1200mm&period;

Approved and listed by&colon; CCS&comma; ISO9001 and CE&period;

Main Components&colon;

1&comma;Insulation
Generally&comma; the phase line is color green&comma; the ground line is yellow-green plastic housing&semi; For H19 system&comma; the standard length is 4&period;5m long&comma; and for other systems&comma; the standard length is 6&period;0m long&period; Other sections are available&period;

2&comma; Joint material
Snap-in joint splices provide mechanical and electrical continuity&period; They include insulated protection covers&period;

3&comma; Feed Sets
Line feeds &lpar;any joints&rpar; or end feeds&period;

4&comma; End caps
The open ends of the conductor are closed by ends caps&period;

5&comma; Hangers
Standard brackets for conductor attachment to crane girders are available&period; Conductor with sliding and fixpoint hangers&period;Standard distance between suspension points for indoor and outdoor installations&colon; 1500mm to 2000mm&period;

6&comma; Expansion section 
The expansion sections are required to compensate the different expansions between copper conductors and steel or concrete structures&comma; in varying temperature without interrupting electrical power&period; Expansion joints are used when the power rail length between feeds&comma; curves&comma; switches or other fix points is exceeding 200m&period; Install one expansion joint according to actually installation&period;

7&comma;Isolating section
Isolating sections are required if parts of the system or individual rails are to be de-energized within a conductor rail system&period; To prevent a voltage bridging by current collector two air gap isolating sections should be installed&period;

8&comma;Switches
Power rail for working areas and transfer applications see End cap

9&comma;Collectors
The current collector are made of carbon brush&comma; re-inforced nylon and galvanized or spray-paint metal spring loaded carbon brushes maintain uniform contact&period; Connecting cables and hinged or flexible towing arms included&period; Double collectors for transfer applicaitions and higher amperage&period;

Technical Data&colon;

Conductor rail system                                                   Program JDC-H
Conductor rail Aluminum Copper Stainless Steel
Type H19 H24 H32 H35 H52 H19 H24 H32 H52 H19
Norminal current at 100&percnt; DC and 35ºC    A 150 250-350 320-1250 230-800 1250-3000 150-500 500-800 800-1600 1250-5000 25
D&period;C&period; resistance at 35ºC  &lsqb;&ohm;&sol;km&rbrack; 0&period;38 0&period;203-0&period;187 0&period;153-0&period;046 0&period;153-0&period;067 0&period;043-0&period;015 0&period;376-0&period;156 0&period;116-0&period;067 0&period;067-0&period;039 0&period;036-0&period;007 11&period;652
Impendance at 35ºC  &lsqb;&ohm;&sol;km&rbrack; 0&period;38 0&period;209-0&period;195 0&period;155-0&period;048 0&period;155-0&period;069 0&period;044-0&period;017 0&period;377-0&period;158 0&period;118-0&period;069  0&period;069-0&period;040 0&period;038-0&period;008 11&period;663
Support spacing &lpar;m&rpar; 1&period;5 1&period;5 1&period;8 1&period;8 2&period;0 1&period;5 1&period;5 1&period;8 2&period;0 1&period;5
Rail length     &lpar;m&rpar; 4&period;5 6&period;0 6&period;0 6&period;0 6&period;0 4&period;5 6&period;0 6&period;0 6&period;0 4&period;5
Housing length  &lpar;m&rpar; 4&period;42 5&period;88 5&period;83 5&period;83 5&period;75 4&period;42 5&period;88 5&period;83 5&period;75 4&period;42
Max&period; voltage    &lpar;V&rpar; 660V Dielectric strength &lpar;KV&sol;mm&rpar;                    30-40
Traveling speed ≤600 m&sol;min Standard GB7251&period;2-2006
Expansion joint not required up to 200m installation length
Flame retardant Class b1-no flaming particles&comma; self-extinguishing
Permissible ambient temperature Standard insulation        

Conductor rail system                                                   Program JDC-H
Conductor rail Aluminum Copper Stainless Steel
Type H19 H24 H32 H35 H52 H19 H24 H32 H52 H19
Norminal current at 100&percnt; DC and 35ºC    A 150 250-350 320-1250 230-800 1250-3000 150-500 500-800 800-1600 1250-5000 25
D&period;C&period; resistance at 35ºC  &lsqb;&ohm;&sol;km&rbrack; 0&period;38 0&period;203-0&period;187 0&period;153-0&period;046 0&period;153-0&period;067 0&period;043-0&period;015 0&period;376-0&period;156 0&period;116-0&period;067 0&period;067-0&period;039 0&period;036-0&period;007 11&period;652
Impendance at 35ºC  &lsqb;&ohm;&sol;km&rbrack; 0&period;38 0&period;209-0&period;195 0&period;155-0&period;048 0&period;155-0&period;069 0&period;044-0&period;017 0&period;377-0&period;158 0&period;118-0&period;069  0&period;069-0&period;040 0&period;038-0&period;008 11&period;663
Support spacing &lpar;m&rpar; 1&period;5 1&period;5 1&period;8 1&period;8 2&period;0 1&period;5 1&period;5 1&period;8 2&period;0 1&period;5
Rail length     &lpar;m&rpar; 4&period;5 6&period;0 6&period;0 6&period;0 6&period;0 4&period;5 6&period;0 6&period;0 6&period;0 4&period;5
Housing length  &lpar;m&rpar; 4&period;42 5&period;88 5&period;83 5&period;83 5&period;75 4&period;42 5&period;88 5&period;83 5&period;75 4&period;42
Max&period; voltage    &lpar;V&rpar; 660V Dielectric strength &lpar;KV&sol;mm&rpar;                    30-40
Traveling speed ≤600 m&sol;min Standard GB7251&period;2-2006
Expansion joint not required up to 200m installation length
Flame retardant Class b1-no flaming particles&comma; self-extinguishing
Permissible ambient temperature Standard insulation                         -30ºC-&plus;70ºC                                                High Temperature insulation       -20ºC- &plus;115ºC                                               
Low temperature insulation       -40ºC- &plus;85ºC

                                                                                             
High Temperature insulation       -20ºC- &plus;115ºC                                                          
Low temperature insulation       -40ºC- &plus;85ºC